How do I use different CO2 concentrations in apsim #2268

Open
PanxinZhang opened this issue Jan 8, 2025 · 2 comments
Open

How do I use different CO2 concentrations in apsim #2268

PanxinZhang opened this issue Jan 8, 2025 · 2 comments

Comments

@PanxinZhang
Copy link

I noticed that there is a CO2 setting in the plant module, can I change it here or just enter it in the Met file?

@peter-devoil
Copy link
Collaborator

Any module can supply a CO2 variable - a manager component, as a column or static variable in the met file, etc..

When the plant module does its daily process, it asks the system for CO2 - if something turns up, it will use it, if not it assumes 350ppm.

Some plant modules omit the co2 sensitivity tables; if they notice that co2 is not 350 (ie they are running in a simulation that is only partially configured for co2), then they'll throw an error.

@PanxinZhang
Copy link
Author

Ok, thank you for your reply