VKW Honeywell DM515 Smartmeter _cos phi nicht Korrekt #12
Comments
Also wenn die M-Bus Daten korrekt empfangen werden und wirklich nur der Wert hin und her springt geh ich mal davon aus das Honeywell vielleicht einen anderen Datentypen verwendet? Kannst du ein rohes, dekodiertes M-Bus Frame schicken? |
VOILA: Encoded raw data stream: |
Sry, falscher Branch... Füge bitte nach Zeile 183 in main.cpp das hinzu:
Und schick mir diese dekodierten daten Aber in dem was du geschickt hast, empfängt er garkeinen Leistungsfaktor (Obis Code 1.0.13.7.0.255 bzw. 01000D0700FF). |
Es könnte aber sogar sein, dass wie im Falle bei Issue #10 (auch VKW) dein Smartmeter gar keinen Leistungsfaktor sendet. |
hallo nochmal Encoded raw data stream: |
Also anhand deiner Daten würd ich sagen: Dein Smartmeter gibt ganz einfach keinen Leistungsfaktor aus. |
Ok, werde mal bei der vkw nachfragen
Von meinem iPhone gesendet
… Am 16.10.2023 um 17:16 schrieb Florian ***@***.***>:
Also ich würd sagen, dein Smartmeter gibt ganz einfach keinen Leistungsfaktor aus.
—
Reply to this email directly, view it on GitHub, or unsubscribe.
You are receiving this because you authored the thread.
|
Hallo Florian,
die VKW schickt kein cosphi über den Mbus!
folgende Daten werden an der Kundenschnittstelle übergeben:
{{8,0-0:1.0.0.255,1,0}, Clock, attribute 1 – OBIS code
{8,0-0:1.0.0.255,2,0}, Clock, attribute 2 – time
{1,0-0:96.1.0.255,0,0}, Device ID 1 manufacturing number, attribute 0 –
OBIS code, serial number
{1,0-0:42.0.0.255,0,0}, COSEM logical device name, attribute 0 – OBIS
code, logical device number
{3,1-0:32.7.0.255,0,0}, Instantaneous voltage L1, attribute 0 – OBIS
code, value, scalar and unit
{3,1-0:31.7.0.255,0,0}, Instantaneous current L1, attribute 0 – OBIS
code, value, scalar and unit
{3,1-0:1.7.0.255,0,0}; Instantaneous active import power (+P), attribute
0 – OBIS code, value, scalar and unit
{3,1-0:2.7.0.255,0,0}; Instantaneous active export power (-P), attribute
0 – OBIS code, value, scalar and unit
{3,1-0:1.8.0.255,0,0}, Active energy import (+A), attribute 0 – OBIS
code, value, scalar and unit
{3,1-0:2.8.0.255,0,0}, Active energy export (-A), attribute 0 – OBIS
code, value, scalar and unit
{3,1-0:3.8.0.255,0,0}, Rective energy import (+R), attribute 0 – OBIS
code, value, scalar and unit
{3,1-0:4.8.0.255,0,0} Rective energy export (-R), attribute 0 – OBIS
code, value, scalar and unit
Die HT/NT Aufteilung der Wirkenergie ist hier nicht enthalten in unserer
Schnittstellenausprägung.
Eine entsprechende Freischaltung ist nicht vorgesehen.
LG Soundrico
Am 2023-10-16 17:16, schrieb Florian:
… Also ich würd sagen, dein Smartmeter gibt ganz einfach keinen
Leistungsfaktor aus.
--
Reply to this email directly, view it on GitHub [1], or unsubscribe
[2].
You are receiving this because you authored the thread.Message ID:
***@***.***>
Links:
------
[1]
#12 (comment)
[2]
https://github.com/notifications/unsubscribe-auth/BDG6M6OCPBK3IM4QQSSZVOLX7VFUHAVCNFSM6AAAAAA55MSEFGVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMYTONRUG4YTQMBUHA
|
Alles klar, danke für die info! |
änderungen im Code (issue 7)
dennoch anzeige de cosphi 0,000 bzw sporadisch 1,983
Ideen?
The text was updated successfully, but these errors were encountered: