Notifications
You must be signed in to change notification settings - Fork 2
Litron Laser Timing Control (Stanford DG645)
Jack Doughty edited this page Dec 20, 2024
·
13 revisions
Litron Laser Timing Control is an extension of the DG645 IOC made for HIFI to use. It replaces the LabView functionality as described here.
By setting a delay and offset the following calculation is done.
dC_0 = Delay + Offset
in us
Under the following constraints:
If mode is 1:
if dC_0 + Delay + Offset > 39900 us
or Delay + Offset < 0 us
then:
Error State
If mode is 2:
if Delay + Offset > 39900 us
or dC_0 + Delay + Offset <= 0 us
then:
Error State
When the user tries to set the mode then the following is applied:
If IOC mode is 1 or 2 then:
Set device mode to be 1 or 2 respectively
else: # IOC mode is auto
if Delay > Offset then:
Set device mode to 1
else:
Set device mode to 2
Note that IOC mode is not the same as device mode. IOC mode refers to a value of auto
or 1
or 2
, the device mode refers to which configuration/setting slot the DG645 is in (0-9). IOC mode 1 and 2 refers to device setting slots 1 and 2.