          The battery percentage is not processed correctly and there is no brightness control.

I am attaching the output of the properties tab and my converter.
I still couldn't figure out how to use the batteries. I deleted the timer schedule on purpose - I don't need it.
I wrote through Google Translate

{
    "battery": 100,
    "battery_percentage": 96,
    "child_lock": "LOCK",
    "current_heating_setpoint": 22,
    "display_brightness": "high",
    "last_seen": "2025-02-07T16:12:20.316Z",
    "linkquality": 228,
    "local_temperature": 24.1,
    "local_temperature_calibration": -3.2,
    "max_temperature": 30,
    "min_temperature": 5,
    "mode": "eco",
    "position": 0,
    "preset": "manual",
    "running_state": "idle",
    "screen_orientation": "up",
    "switch_type": "ON",
    "system_mode": "auto",
    "update": {
        "installed_version": 73,
        "latest_version": 73,
        "state": "idle"
    },
    "window": "CLOSE",
    "window_detection": "ON",
    "working_status": 240
}
const legacy = require('zigbee-herdsman-converters/lib/legacy');
const fz = {...require('zigbee-herdsman-converters/converters/fromZigbee'), legacy: require('zigbee-herdsman-converters/lib/legacy').fromZigbee};
const tz = {...require('zigbee-herdsman-converters/converters/toZigbee'), legacy: require('zigbee-herdsman-converters/lib/legacy').toZigbee};
const exposes = require('zigbee-herdsman-converters/lib/exposes');
const reporting = require('zigbee-herdsman-converters/lib/reporting');
const ota = require('zigbee-herdsman-converters/lib/ota');
const utils = require('zigbee-herdsman-converters/lib/utils');
const globalStore = require('zigbee-herdsman-converters/lib/store');
const tuya = require('zigbee-herdsman-converters/lib/tuya');
const e = exposes.presets;
const ea = exposes.access;

const definition = {
    zigbeeModel: ['TS0601'],
    fingerprint: [
        {modelID: 'TS0601', manufacturerName: '_TZE204_cvcu2p6e'}, //Thaleos Connect
    ],
    model: 'SBDV-00185',
    vendor: 'Sber',
    description: 'Sber Smart Thermostat',
    fromZigbee: [fz.cover_position_tilt, tuya.fz.datapoints],
    toZigbee: [tz.cover_position_tilt, tz.cover_state, tuya.tz.datapoints],
    onEvent: tuya.onEventSetTime,
        configure: tuya.configureMagicPacket,
        ota: ota.zigbeeOTA,
        exposes: [
            e.battery('battery_percentage'),
            e.child_lock(),
            e.max_temperature(),
            e.min_temperature(),
            e.position(),
            e.window_detection(),
            e.binary('window', ea.STATE, 'OPEN', 'CLOSE').withDescription('Window status closed or open '),
            e.binary('alarm_switch', ea.STATE, 'ON', 'OFF').withDescription('Thermostat in error state'),
            e
                .climate()
                .withLocalTemperature(ea.STATE)
                .withSetpoint('current_heating_setpoint', 5, 30, 0.5, ea.STATE_SET)
                .withLocalTemperatureCalibration(-10, 10, 0.1, ea.STATE_SET)
                .withPreset(
                    ['auto', 'manual', 'off', 'on'],
                    'MANUAL MODE ☝ - In this mode, the device executes manual temperature setting. ' +
                        'When the set temperature is lower than the "minimum temperature", the valve is closed (forced closed). ' +
                        'AUTO MODE ⏱ - In this mode, the device executes a preset week programming temperature time and temperature. ' +
                        'ON - In this mode, the thermostat stays open ' +
                        'OFF - In this mode, the thermostat stays closed',
                )
                .withRunningState(['idle', 'heat'], ea.STATE),
            e.enum('display_brightness', ea.STATE_SET, ['high', 'medium', 'low']).withDescription('Display brightness'),
            e.enum('screen_orientation', ea.STATE_SET, ['up',  'down']).withDescription('Screen orientation'),
            e
                .enum('mode', ea.STATE_SET, ['comfort', 'eco'])
                .withDescription(
                    'Hysteresis - comfort > switches off/on exactly at reached ' +
                        'temperature with valve smooth from 0 to 100%, eco > 0.5 degrees above or below, valve either 0 or 100%',
                ),
        ],
        meta: {
            tuyaDatapoints: [
                //[1, 'system_mode', tuya.valueConverter.thermostatSystemModeAndPreset('system_mode')],
                [1, 'preset', tuya.valueConverter.thermostatSystemModeAndPreset('preset')],
                [2, 'current_heating_setpoint', tuya.valueConverter.divideBy10],
                [3, 'local_temperature', tuya.valueConverter.divideBy10],
                [6, 'running_state', tuya.valueConverterBasic.lookup({heat: 1, idle: 0})],
                [7, 'window', tuya.valueConverterBasic.lookup({OPEN: 1, CLOSE: 0})],
                [8, 'window_detection', tuya.valueConverter.onOff],
                //[10, 'battery', tuya.valueConverter.raw],
                [12, 'child_lock', tuya.valueConverter.lockUnlock],
                [13, 'battery_percentage', tuya.valueConverter.raw],
                [14, 'alarm_switch', tuya.valueConverter.onOff],
                [15, 'min_temperature', tuya.valueConverter.divideBy10],
                [16, 'max_temperature', tuya.valueConverter.divideBy10],
                [101, 'local_temperature_calibration', tuya.valueConverter.localTempCalibration1],
                [102, 'frost_protection', tuya.valueConverter.onOff],
                [103, 'factory_reset', tuya.valueConverter.onOff],
                [106, 'sensor', tuya.valueConverterBasic.lookup({internal: tuya.enum(0), external: tuya.enum(1), both: tuya.enum(2)})],
                [107, 'temperature_delta', tuya.valueConverter.divideBy10],                
                [108, 'position', tuya.valueConverter.divideBy10],
                [111, 'display_brightness', tuya.valueConverterBasic.lookup({high: tuya.enum(0), medium: tuya.enum(1), low: tuya.enum(2)})],
                [
                    113,
                    'screen_orientation',
                    tuya.valueConverterBasic.lookup({
                        up: tuya.enum(0),
                        down: tuya.enum(2),
                    }),
                ],
                [114, 'mode', tuya.valueConverterBasic.lookup({comfort: tuya.enum(0), eco: tuya.enum(1)})],
            ],
        },
};

module.exports = definition;

Originally posted by @faplug in #8677 (comment)