Skip to content

Commit

Permalink
added a few electrolysis data sources
Browse files Browse the repository at this point in the history
  • Loading branch information
clarabachorz committed Oct 23, 2024
1 parent 960f4b6 commit 146db7e
Show file tree
Hide file tree
Showing 2 changed files with 157 additions and 6 deletions.
53 changes: 52 additions & 1 deletion inst/extdata/database/sources.bib
Original file line number Diff line number Diff line change
Expand Up @@ -1123,4 +1123,55 @@ @article{Brynolf18
month = jan,
year = {2018},
pages = {1887--1905},
}
}

@techreport{Indwede18,
address = {Berlin},
title = {{IndWEDe}: {Industrialisierung} der {Wasserelektrolyse} in {Deutschland}: {Chancen} und {Herausforderungen} für nachhaltigen {Wasserstoff} für {Verkehr}, {Strom} und {Wärme}},
url = {https://www.now-gmbh.de/wp-content/uploads/2020/09/indwede-studie_v04.1.pdf},
language = {de},
institution = {NOW GmbH},
author = {Smolinka, Tom and Wiebe, Nikolai and Sterchele, Philip and Palzer, Andreas},
year = {2018},
}

@techreport{FCH17,
address = {Brussels},
title = {{EARLY} {BUSINESS} {CASES} {FOR} {H2} {IN} {ENERGY} {STORAGE} {AND} {MORE} {BROADLY} {POWER} {TO} {H2} {APPLICATIONS}},
url = {https://hsweb.hs.uni-hamburg.de/projects/star-formation/hydrogen/P2H_Full_Study_FCHJU.pdf},
language = {en},
institution = {FCH},
author = {Chardonnet, C and de Vos, L and Genoese, F and Roig, G and Bart, F and De Lacroix, T and Ha, T and Van Genabet, B},
year = {2017},
}

@techreport{DOE24,
title = {Clean {Hydrogen} {Production} {Cost} {Scenarios} with {PEM} {Electrolyzer} {Technology}},
url = {https://www.hydrogen.energy.gov/docs/hydrogenprogramlibraries/pdfs/24005-clean-hydrogen-production-cost-pem-electrolyzer.pdf?sfvrsn=8cb10889_1},
institution = {DOE},
author = {Hubert, McKenzie and Peterson, David and Miller, Eric and Vickers, James and Mow, Rachel and Howe, Campbell},
year = {2024},
}

@article{Krishnan23,
title = {Present and future cost of alkaline and {PEM} electrolyser stacks},
volume = {48},
issn = {0360-3199},
url = {https://www.sciencedirect.com/science/article/pii/S0360319923022590},
doi = {10.1016/j.ijhydene.2023.05.031},
number = {83},
journal = {International Journal of Hydrogen Energy},
author = {Krishnan, Subramani and Koning, Vinzenz and Theodorus de Groot, Matheus and de Groot, Arend and Mendoza, Paola Granados and Junginger, Martin and Kramer, Gert Jan},
year = {2023},
}

@article{Nami22,
title = {Techno-economic analysis of current and emerging electrolysis technologies for green hydrogen production},
volume = {269},
issn = {0196-8904},
url = {https://www.sciencedirect.com/science/article/pii/S0196890422009438},
doi = {10.1016/j.enconman.2022.116162},
journal = {Energy Conversion and Management},
author = {Nami, Hossein and Rizvandi, Omid Babaie and Chatzichristodoulou, Christodoulos and Hendriksen, Peter Vang and Frandsen, Henrik Lund},
year = {2022},
}
110 changes: 105 additions & 5 deletions inst/extdata/database/tedfs/Tech/Electrolysis.csv
Original file line number Diff line number Diff line change
Expand Up @@ -44,6 +44,56 @@ AEL,*,CAPEX,Input Capacity|Electricity,2030,700.0,,EUR_2015,1.0,kW,,Brynolf18,"T
PEM,*,CAPEX,Input Capacity|Electricity,2018,2400.0,,EUR_2015,1.0,kW,,Brynolf18,"Table 3"
PEM,*,CAPEX,Input Capacity|Electricity,2030,800.0,,EUR_2015,1.0,kW,,Brynolf18,"Table 3"
SOEC,*,CAPEX,Input Capacity|Electricity,2030,700.0,,EUR_2015,1.0,kW,,Brynolf18,"Table 3"
AEL,*,CAPEX,Output Capacity|Hydrogen,2017,620.0,,EUR_2017,1.0,kW,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
AEL,*,CAPEX,Output Capacity|Hydrogen,2030,410.0,,EUR_2017,1.0,kW,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
AEL,*,CAPEX,Output Capacity|Hydrogen,2050,250.0,,EUR_2017,1.0,kW,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
PEM,*,CAPEX,Output Capacity|Hydrogen,2017,1390.0,,EUR_2017,1.0,kW,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
PEM,*,CAPEX,Output Capacity|Hydrogen,2030,490.0,,EUR_2017,1.0,kW,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
PEM,*,CAPEX,Output Capacity|Hydrogen,2050,210.0,,EUR_2017,1.0,kW,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
SOEC,*,CAPEX,Output Capacity|Hydrogen,2017,1350.0,,EUR_2017,1.0,kW,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
SOEC,*,CAPEX,Output Capacity|Hydrogen,2030,310.0,,EUR_2017,1.0,kW,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
SOEC,*,CAPEX,Output Capacity|Hydrogen,2050,160.0,,EUR_2017,1.0,kW,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
AEL,*,CAPEX,Output Capacity|Hydrogen,2017,920.0,,EUR_2017,1.0,kW,"Central assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
AEL,*,CAPEX,Output Capacity|Hydrogen,2030,690.0,,EUR_2017,1.0,kW,"Central assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
AEL,*,CAPEX,Output Capacity|Hydrogen,2050,500.0,,EUR_2017,1.0,kW,"Central assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
PEM,*,CAPEX,Output Capacity|Hydrogen,2017,1470.0,,EUR_2017,1.0,kW,"Central assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
PEM,*,CAPEX,Output Capacity|Hydrogen,2030,810.0,,EUR_2017,1.0,kW,"Central assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
PEM,*,CAPEX,Output Capacity|Hydrogen,2050,510.0,,EUR_2017,1.0,kW,"Central assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
SOEC,*,CAPEX,Output Capacity|Hydrogen,2017,2300.0,,EUR_2017,1.0,kW,"Central assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
SOEC,*,CAPEX,Output Capacity|Hydrogen,2030,460.0,,EUR_2017,1.0,kW,"Central assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
SOEC,*,CAPEX,Output Capacity|Hydrogen,2050,280.0,,EUR_2017,1.0,kW,"Central assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
AEL,*,CAPEX,Output Capacity|Hydrogen,2017,1220.0,,EUR_2017,1.0,kW,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
AEL,*,CAPEX,Output Capacity|Hydrogen,2030,970.0,,EUR_2017,1.0,kW,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
AEL,*,CAPEX,Output Capacity|Hydrogen,2050,750.0,,EUR_2017,1.0,kW,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
PEM,*,CAPEX,Output Capacity|Hydrogen,2017,1540.0,,EUR_2017,1.0,kW,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
PEM,*,CAPEX,Output Capacity|Hydrogen,2030,1120.0,,EUR_2017,1.0,kW,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
PEM,*,CAPEX,Output Capacity|Hydrogen,2050,800.0,,EUR_2017,1.0,kW,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
SOEC,*,CAPEX,Output Capacity|Hydrogen,2017,3250.0,,EUR_2017,1.0,kW,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
SOEC,*,CAPEX,Output Capacity|Hydrogen,2030,610.0,,EUR_2017,1.0,kW,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
SOEC,*,CAPEX,Output Capacity|Hydrogen,2050,400.0,,EUR_2017,1.0,kW,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle 4-1"
AEL,1 MW,CAPEX,Output Capacity|Hydrogen,2017,1200.0,,EUR_2017,1.0,kW,"Not including stack replacement. At atmospheric pressure.",FCH17,"Table 24"
AEL,5 MW,CAPEX,Output Capacity|Hydrogen,2017,830.0,,EUR_2017,1.0,kW,"Not including stack replacement. At atmospheric pressure.",FCH17,"Table 24"
AEL,20 MW,CAPEX,Output Capacity|Hydrogen,2017,750.0,,EUR_2017,1.0,kW,"Not including stack replacement. At atmospheric pressure.",FCH17,"Table 24"
AEL,1 MW,CAPEX,Output Capacity|Hydrogen,2025,900.0,,EUR_2017,1.0,kW,"Not including stack replacement. At 15 bar.",FCH17,"Table 24"
AEL,5 MW,CAPEX,Output Capacity|Hydrogen,2025,600.0,,EUR_2017,1.0,kW,"Not including stack replacement. At 15 bar.",FCH17,"Table 24"
AEL,20 MW,CAPEX,Output Capacity|Hydrogen,2025,480.0,,EUR_2017,1.0,kW,"Not including stack replacement. At 15 bar.",FCH17,"Table 24"
PEM,1 MW,CAPEX,Output Capacity|Hydrogen,2017,1500.0,,EUR_2017,1.0,kW,"Not including stack replacement. At 30 bar.",FCH17,"Table 24"
PEM,5 MW,CAPEX,Output Capacity|Hydrogen,2017,1300.0,,EUR_2017,1.0,kW,"Not including stack replacement. At 30 bar.",FCH17,"Table 24"
PEM,20 MW,CAPEX,Output Capacity|Hydrogen,2017,1200.0,,EUR_2017,1.0,kW,"Not including stack replacement. At 30 bar.",FCH17,"Table 24"
PEM,1 MW,CAPEX,Output Capacity|Hydrogen,2025,1000.0,,EUR_2017,1.0,kW,"Not including stack replacement. At 60 bar.",FCH17,"Table 24"
PEM,5 MW,CAPEX,Output Capacity|Hydrogen,2025,900.0,,EUR_2017,1.0,kW,"Not including stack replacement. At 60 bar.",FCH17,"Table 24"
PEM,20 MW,CAPEX,Output Capacity|Hydrogen,2025,700.0,,EUR_2017,1.0,kW,"Not including stack replacement. At 60 bar.",FCH17,"Table 24"
PEM,*,CAPEX,Output Capacity|Hydrogen,2024,2000.0,500,USD_2022,1.0,kW,"Central assumption",DOE24,"Table 1"
PEM,*,CAPEX,Output Capacity|Hydrogen,2030,359.0,,EUR_2023,1.0,kW,"Low assumption",Krishnan23,"Table 5"
PEM,*,CAPEX,Output Capacity|Hydrogen,2030,1300.0,,EUR_2023,1.0,kW,"High assumption",Krishnan23,"Table 5"
AEL,*,CAPEX,Output Capacity|Hydrogen,2030,372.0,,EUR_2023,1.0,kW,"Low assumption",Krishnan23,"Table 5"
AEL,*,CAPEX,Output Capacity|Hydrogen,2030,564.0,,EUR_2023,1.0,kW,"High assumption",Krishnan23,"Table 5"
AEL,*,CAPEX,Output Capacity|Hydrogen,2020,830.0,0.0,EUR_2022,1.0,kW,"Low temperature and pressure electrolyser",Nami22,"Table 7"
AEL,*,CAPEX,Output Capacity|Hydrogen,2030,670.0,0.0,EUR_2022,1.0,kW,"Low temperature and pressure electrolyser",Nami22,"Table 7"
AEL,*,CAPEX,Output Capacity|Hydrogen,2050,300.0,0.0,EUR_2022,1.0,kW,"Low temperature and pressure electrolyser",Nami22,"Table 7"
SOEC,*,CAPEX,Output Capacity|Hydrogen,2020,2770.0,0.0,EUR_2022,1.0,kW,"Low pressure electrolyser",Nami22,"Table 7"
SOEC,*,CAPEX,Output Capacity|Hydrogen,2030,1140.0,0.0,EUR_2022,1.0,kW,"Low and pressure electrolyser",Nami22,"Table 7"
SOEC,*,CAPEX,Output Capacity|Hydrogen,2050,400.0,0.0,EUR_2022,1.0,kW,"Low pressure electrolyser",Nami22,"Table 7"
AEL,100 MW,OPEX Fixed,Input Capacity|Electricity,2020,6.0,,EUR_2020/a,1.0,kW,1.5% of CAPEX; reported in units of electric capacity,Vartiainen22,Page 4
AEL,100 MW,OPEX Fixed,Input Capacity|Electricity,2030,2.1,,EUR_2020/a,1.0,kW,10% LR decrease,Vartiainen22,Page 4
AEL,100 MW,OPEX Fixed,Input Capacity|Electricity,2040,0.73,,EUR_2020/a,1.0,kW,10% LR decrease,Vartiainen22,Page 4
Expand All @@ -59,8 +109,16 @@ SOEC,1 MW,OPEX Fixed Relative,,*,12.0,,percent,,,,DEARF23,"Sheet 86 SOEC 1MW, Ro
AEL,*,OPEX Fixed Relative,,2018,3.5,1.5,percent,,,,Brynolf18,"Table 3"
AEL,*,OPEX Fixed Relative,,2030,3.5,1.5,percent,,,,Brynolf18,"Table 3"
PEM,*,OPEX Fixed Relative,,2018,3.5,1.5,percent,,,,Brynolf18,"Table 3"
PEM,*,OPEX Fixed Relative,,3.5,1.5,percent,,,,,Brynolf18,"Table 3"
PEM,*,OPEX Fixed Relative,,2030,3.5,1.5,percent,,,,Brynolf18,"Table 3"
SOEC,*,OPEX Fixed Relative,,2030,2.5,0.5,percent,,,,Brynolf18,"Table 3"
AEL,*,Lifetime,,2018,25,5,year,,,"Overall system life span (stack typically needs to be replaced halfway)",Brynolf18,Table 3
AEL,*,Lifetime,,2030,30,,year,,,"Overall system life span (stack typically needs to be replaced halfway)",Brynolf18,Table 3
PEM,*,Lifetime,,2018,20,10,year,,,"Overall system life span (stack typically needs to be replaced halfway)",Brynolf18,Table 3
PEM,*,Lifetime,,2030,30,,year,,,"Overall system life span (stack typically needs to be replaced halfway)",Brynolf18,Table 3
SOEC,*,Lifetime,,2030,15,5,year,,,"Overall system life span (stack typically needs to be replaced halfway)",Brynolf18,Table 3
AEL,*,Lifetime,,*,20,,year,,,"Overall system life span.",FCH17,"Table 24"
PEM,*,Lifetime,,*,20,,year,,,"Overall system life span.",FCH17,"Table 24"
PEM,*,Lifetime,,2024,30,,year,,,,DOE24,"Table 1"
AEL,100 MW,Output|Hydrogen,Input|Electricity,2020,67.0,,pct kWh;LHV,100.0,pct kWh,1.5% of CAPEX; reported in units of electric capacity; 67% assumes the LHV,Vartiainen22,Page 4
AEL,100 MW,Output|Hydrogen,Input|Electricity,2030,70.0,,pct kWh;LHV,100.0,pct kWh,10% LR decrease,Vartiainen22,Page 4
AEL,100 MW,Output|Hydrogen,Input|Electricity,2040,73.0,,pct kWh;LHV,100.0,pct kWh,10% LR decrease,Vartiainen22,Page 4
Expand All @@ -77,12 +135,14 @@ SOEC,*,Output|Hydrogen,Input|Electricity,2020,23.3,1.0,kg,1.0,MWh,,DEARF23,"Shee
SOEC,*,Output|Hydrogen,Input|Electricity,2030,24.2,,kg,1.0,MWh,,DEARF23,"Sheet 86 SOEC 1MW, Row 16"
SOEC,*,Output|Hydrogen,Input|Electricity,2040,24.6,,kg,1.0,MWh,,DEARF23,"Sheet 86 SOEC 1MW, Row 16"
SOEC,*,Output|Hydrogen,Input|Electricity,2050,25.1,0.5,kg,1.0,MWh,,DEARF23,"Sheet 86 SOEC 1MW, Row 16"

AEL,,Output|Hydrogen,Input|Electricity,2018,65.0,,pct kWh;LHV,100.0,pct kWh,"Efficiency assumes the LHV",Brynolf18,Table 3
AEL,,Output|Hydrogen,Input|Electricity,2030,66.0,,pct kWh;LHV,100.0,pct kWh,"Efficiency assumes the LHV",Brynolf18,Table 3
PEM,,Output|Hydrogen,Input|Electricity,2018,65.0,,pct kWh;LHV,100.0,pct kWh,"Efficiency assumes the LHV",Brynolf18,Table 3
PEM,,Output|Hydrogen,Input|Electricity,2030,66.0,,pct kWh;LHV,100.0,pct kWh,"Efficiency assumes the LHV",Brynolf18,Table 3

PEM,,Output|Hydrogen,Input|Electricity,2018,62.0,,pct kWh;LHV,100.0,pct kWh,"Efficiency assumes the LHV",Brynolf18,Table 3
PEM,,Output|Hydrogen,Input|Electricity,2030,69.0,,pct kWh;LHV,100.0,pct kWh,"Efficiency assumes the LHV",Brynolf18,Table 3
SOEC,,Output|Hydrogen,Input|Electricity,2030,77.0,,pct kWh;LHV,100.0,pct kWh,"Steam SOEC only. Efficiency assumes the LHV",Brynolf18,Table 3
AEL,*,Output|Hydrogen,Input|Electricity,*,66.0,0.0,pct kWh;LHV,100.0,pct kWh,"Low temperature and pressure electrolyser (80°)",Nami22,"Table 9"
SOEC,*,Output|Hydrogen,Input|Electricity,*,76.0,0.0,pct kWh;LHV,100.0,pct kWh,"Low pressure electrolyser, includes downstream compression to 30 bar.",Nami22,"Table 9"
SOEC,*,Output|Hydrogen,Input|Electricity,*,89.0,0.0,pct kWh;LHV,100.0,pct kWh,"Low pressure electrolyser, includes downstream compression to 30 bar. With free steam.",Nami22,"Table 9"
SOEC,*,Input|Heat,Input|Electricity,2020,20.5,2.0,pct MWh,79.5,pct MWh,,DEARF23,"Sheet 86 SOEC 1MW, Rows 9 and 10"
SOEC,*,Input|Heat,Input|Electricity,2030,19.5,,pct MWh,80.5,pct MWh,,DEARF23,"Sheet 86 SOEC 1MW, Rows 9 and 10"
SOEC,*,Input|Heat,Input|Electricity,2040,18.6,,pct MWh,81.4,pct MWh,,DEARF23,"Sheet 86 SOEC 1MW, Rows 9 and 10"
Expand All @@ -103,6 +163,46 @@ PEM,130000 Nm³/h,Input|Electricity,Output|Hydrogen,2030,4.81,,kWh,1.0,m³;norm,
SOEC,130000 Nm³/h,Input|Electricity,Output|Hydrogen,2030,3.55,,kWh,1.0,m³;norm,Total system demand,Tenhumberg20,"Table 2, Page 1588 (3/10)"
SOEC,130000 Nm³/h,Input|Heat,Output|Hydrogen,2030,0.7,,kWh,1.0,m³;norm,Total system demand,Tenhumberg20,"Table 3, Page 1590 (5/10)"
AEL,*,Input|Electricity,Output|Hydrogen,2020,54.0,4.0,kWh,1.0,kg,,Yates20,"Table 3, Page 10"
AEL,*,Input|Electricity,Output|Hydrogen,2017,48.70,,kWh,1.0,kg,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle A4"
AEL,*,Input|Electricity,Output|Hydrogen,2030,47.10,,kWh,1.0,kg,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle A4"
AEL,*,Input|Electricity,Output|Hydrogen,2050,47.10,,kWh,1.0,kg,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle A4"
PEM,*,Input|Electricity,Output|Hydrogen,2017,52.90,,kWh,1.0,kg,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle A4"
PEM,*,Input|Electricity,Output|Hydrogen,2030,49.20,,kWh,1.0,kg,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle A4"
PEM,*,Input|Electricity,Output|Hydrogen,2050,45.30,,kWh,1.0,kg,"Progressive assumption. From an industry survey.",Indwede18,"Tabelle A4"
SOEC,*,Input|Electricity,Output|Hydrogen,2017,41.20,,kWh,1.0,kg,"Progressive assumption. From an industry survey. Excludes steam production.",Indwede18,"Tabelle A4"
SOEC,*,Input|Electricity,Output|Hydrogen,2030,40.00,,kWh,1.0,kg,"Progressive assumption. From an industry survey. Excludes steam production.",Indwede18,"Tabelle A4"
SOEC,*,Input|Electricity,Output|Hydrogen,2050,40.00,,kWh,1.0,kg,"Progressive assumption. From an industry survey. Excludes steam production.",Indwede18,"Tabelle A4"
AEL,*,Input|Electricity,Output|Hydrogen,2017,51.80,,kWh,1.0,kg,"Central assumption. From an industry survey.",Indwede18,"Tabelle A4"
AEL,*,Input|Electricity,Output|Hydrogen,2030,49.70,,kWh,1.0,kg,"Central assumption. From an industry survey.",Indwede18,"Tabelle A4"
AEL,*,Input|Electricity,Output|Hydrogen,2050,48.50,,kWh,1.0,kg,"Central assumption. From an industry survey.",Indwede18,"Tabelle A4"
PEM,*,Input|Electricity,Output|Hydrogen,2017,54.00,,kWh,1.0,kg,"Central assumption. From an industry survey.",Indwede18,"Tabelle A4"
PEM,*,Input|Electricity,Output|Hydrogen,2030,53.70,,kWh,1.0,kg,"Central assumption. From an industry survey.",Indwede18,"Tabelle A4"
PEM,*,Input|Electricity,Output|Hydrogen,2050,48.90,,kWh,1.0,kg,"Central assumption. From an industry survey.",Indwede18,"Tabelle A4"
SOEC,*,Input|Electricity,Output|Hydrogen,2017,42.30,,kWh,1.0,kg,"Central assumption. From an industry survey. Excludes steam production.",Indwede18,"Tabelle A4"
SOEC,*,Input|Electricity,Output|Hydrogen,2030,40.60,,kWh,1.0,kg,"Central assumption. From an industry survey. Excludes steam production.",Indwede18,"Tabelle A4"
SOEC,*,Input|Electricity,Output|Hydrogen,2050,40.60,,kWh,1.0,kg,"Central assumption. From an industry survey. Excludes steam production.",Indwede18,"Tabelle A4"
AEL,*,Input|Electricity,Output|Hydrogen,2017,54.90,,kWh,1.0,kg,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle A4"
AEL,*,Input|Electricity,Output|Hydrogen,2030,52.40,,kWh,1.0,kg,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle A4"
AEL,*,Input|Electricity,Output|Hydrogen,2050,49.90,,kWh,1.0,kg,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle A4"
PEM,*,Input|Electricity,Output|Hydrogen,2017,55.10,,kWh,1.0,kg,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle A4"
PEM,*,Input|Electricity,Output|Hydrogen,2030,58.10,,kWh,1.0,kg,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle A4"
PEM,*,Input|Electricity,Output|Hydrogen,2050,52.50,,kWh,1.0,kg,"Conservative assumption. From an industry survey.",Indwede18,"Tabelle A4"
SOEC,*,Input|Electricity,Output|Hydrogen,2017,43.40,,kWh,1.0,kg,"Conservative assumption. From an industry survey. Excludes steam production.",Indwede18,"Tabelle A4"
SOEC,*,Input|Electricity,Output|Hydrogen,2030,41.20,,kWh,1.0,kg,"Conservative assumption. From an industry survey. Excludes steam production.",Indwede18,"Tabelle A4"
SOEC,*,Input|Electricity,Output|Hydrogen,2050,41.20,,kWh,1.0,kg,"Conservative assumption. From an industry survey. Excludes steam production.",Indwede18,"Tabelle A4"
AEL,1 MW,Input|Electricity,Output|Hydrogen,2017,58,,kWh,1.0,kg,"At atmospheric pressure.",FCH17,"Table 24"
AEL,5 MW,Input|Electricity,Output|Hydrogen,2017,52,,kWh,1.0,kg,"At atmospheric pressure.",FCH17,"Table 24"
AEL,20 MW,Input|Electricity,Output|Hydrogen,2017,51,,kWh,1.0,kg,"At atmospheric pressure.",FCH17,"Table 24"
AEL,1 MW,Input|Electricity,Output|Hydrogen,2025,55,,kWh,1.0,kg,"At 15 bar.",FCH17,"Table 24"
AEL,5 MW,Input|Electricity,Output|Hydrogen,2025,50,,kWh,1.0,kg,"At 15 bar.",FCH17,"Table 24"
AEL,20 MW,Input|Electricity,Output|Hydrogen,2025,49,,kWh,1.0,kg,"At 15 bar.",FCH17,"Table 24"
PEM,1 MW,Input|Electricity,Output|Hydrogen,2017,63,,kWh,1.0,kg,"At 30 bar.",FCH17,"Table 24"
PEM,5 MW,Input|Electricity,Output|Hydrogen,2017,61,,kWh,1.0,kg,"At 30 bar.",FCH17,"Table 24"
PEM,20 MW,Input|Electricity,Output|Hydrogen,2017,58,,kWh,1.0,kg,"At 30 bar.",FCH17,"Table 24"
PEM,1 MW,Input|Electricity,Output|Hydrogen,2025,54,,kWh,1.0,kg,"At 60 bar.",FCH17,"Table 24"
PEM,5 MW,Input|Electricity,Output|Hydrogen,2025,53,,kWh,1.0,kg,"At 60 bar.",FCH17,"Table 24"
PEM,20 MW,Input|Electricity,Output|Hydrogen,2025,52,,kWh,1.0,kg,"At 60 bar.",FCH17,"Table 24"
PEM,*,Input|Electricity,Output|Hydrogen,2024,57,,kWh,1.0,kg,,DOE24,"Table 1"
PEM,*,Input|Water,Output|Hydrogen,2020,10.0,,kg,1.0,kg,"Based on life cycle inventory, from Ecoinvent v3.4",Al-Qahtani21,"Table 2, Page 3"
*,*,Input|Water,Output|Hydrogen,2021,9.0,,kg,1.0,kg,,IEA-GHR21,
AEL,*,Input|Water,Output|Hydrogen,2020,10.0,1.0,L;norm,1.0,kg,,Yates20,"Table 3, Page 10"
Expand Down

0 comments on commit 146db7e