CREATE TABLE farm
(
farm_id int NOT NULL,
description varchar(191),
PRIMARY KEY (farm_id)
);
CREATE TABLE arduino
(
arduino_id int NOT NULL,
farm_id int NOT NULL,
PRIMARY KEY (arduino_id),
FOREIGN KEY (farm_id) REFERENCES farm(farm_id) ON DELETE cascade
);
CREATE TABLE collection(
collection_id int NOT NULL,
time DATE NOT NULL,
PRIMARY KEY (collection_id)
);
CREATE TABLE supply_reading
(
supply_id int NOT NULL,
arduino_id int NOT NULL,
collection_id int NOT NULL,
excess_water int NOt NULL,
nutrient_ed FLOAT(2) NOT NULL,
water_ph FLOAT(2) NOT NULL,
supply_pressure FLOAT(2) NOT NULL,
supply_pump BOOLEAN,
supply_3_way BOOLEAN,
supply_sprinkler BOOLEAN,
PRIMARY KEY (supply_id),
FOREIGN KEY (arduino_id) REFERENCES arduino(arduino_id) ON DELETE cascade,
FOREIGN KEY (collection_id) REFERENCES collection(collection_id) ON DELETE cascade
);
CREATE TABLE return_line
(
return_id int NOT NULL,
arduino_id int NOT NULL,
collection_id int NOT NULL,
farm_runoff_lvl FLOAT(2) NOT NULL,
freshwater_lvl FLOAT(2) NOT NULL,
return_pump BOOLEAN,
return_3_way BOOLEAN,
PRIMARY KEY (return_id),
FOREIGN KEY (arduino_id) REFERENCES arduino(arduino_id) ON DELETE cascade,
FOREIGN KEY (collection_id) REFERENCES collection(collection_id) ON DELETE cascade
);
CREATE TABLE nutrient_zone
(
nutrient_id int NOT NULL,
arduino_id int NOT NULL,
collection_id int NOT NULL,
tank_ph_lvl FLOAT(2) NOT NULL,
tank_A_lvl FLOAT(2) NOT NULL,
tank_B_lvl FLOAT(2) NOT NULL,
nutrient_pump BOOLEAN,
PRIMARY KEY (nutrient_id),
FOREIGN KEY (arduino_id) REFERENCES arduino(arduino_id) ON DELETE cascade,
FOREIGN KEY (collection_id) REFERENCES collection(collection_id) ON DELETE cascade
);
CREATE TABLE weight_sensor
(
sensor_id int NOT NULL,
PRIMARY KEY (sensor_id)
);
CREATE TABLE growth_zone(
growth_id int NOT NULL,
arduino_id int NOT NULL,
collection_id int NOT NULL,
sensor_id int NOT NULL,
ambient_temp FLOAT(2) NOT NULL,
webcam_live BOOLEAN NOT NULL,
plant_weight FLOAT(2) NOT NULL,
light_intensity_1 BOOLEAN,
light_intensity_2 BOOLEAN,
PRIMARY KEY (growth_id),
FOREIGN KEY (arduino_id) REFERENCES arduino(arduino_id) ON DELETE cascade,
FOREIGN KEY (collection_id) REFERENCES collection(collection_id) ON DELETE cascade,
FOREIGN KEY (sensor_id) REFERENCES weight_sensor(sensor_id) ON DELETE cascade
);