Notifications
You must be signed in to change notification settings - Fork 5
/
Copy pathtemplate.yaml
155 lines (136 loc) · 7.24 KB
/
template.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
- sensor:
- name: "Grid Voltage"
state: >
{% set gd_items = state_attr('sensor.inverter_data', 'gd_') %}
{{ (gd_items | selectattr('id', 'equalto', 'gd_grid_voltage') | map(attribute='val') | first) | float }}
unit_of_measurement: "V"
device_class: "voltage"
state_class: "measurement"
- name: "Grid Frequency"
state: >
{% set gd_items = state_attr('sensor.inverter_data', 'gd_') %}
{{ (gd_items | selectattr('id', 'equalto', 'gd_rid_frequency') | map(attribute='val') | first) | float }}
unit_of_measurement: "Hz"
device_class: "frequency"
state_class: "measurement"
- name: "Grid Power"
state: >
{% set gd_items = state_attr('sensor.inverter_data', 'gd_') %}
{% set bt_items = state_attr('sensor.inverter_data', 'bt_') %}
{% set bc_items = state_attr('sensor.inverter_data', 'bc_') %}
{% set grid_voltage = (gd_items | selectattr('id', 'equalto', 'gd_grid_voltage') | map(attribute='val') | first) | float %}
{% set charging_current = (bt_items | selectattr('id', 'equalto', 'bt_battery_charging_current') | map(attribute='val') | first) | float %}
{% set battery_voltage = (bt_items | selectattr('id', 'equalto', 'bt_battery_voltage') | map(attribute='val') | first) | float %}
{% set load_power = (bc_items | selectattr('id', 'equalto', 'bc_load_active_power') | map(attribute='val') | first) | float %}
{% if grid_voltage > 0 %}
{{ (charging_current * battery_voltage) + load_power }}
{% else %}
0
{% endif %}
unit_of_measurement: "W"
device_class: "power"
state_class: "measurement"
- name: "PV1 Voltage"
state: >
{% set pv_items = state_attr('sensor.inverter_data', 'pv_') %}
{{ (pv_items | selectattr('id', 'equalto', 'pv_voltage1') | map(attribute='val') | first) | float }}
unit_of_measurement: "V"
device_class: "voltage"
state_class: "measurement"
- name: "PV1 Current"
state: >
{% set pv_items = state_attr('sensor.inverter_data', 'pv_') %}
{{ (pv_items | selectattr('id', 'equalto', 'pv_curr1') | map(attribute='val') | first) | float }}
unit_of_measurement: "A"
device_class: "current"
state_class: "measurement"
- name: "PV1 Power"
state: >
{% set pv_items = state_attr('sensor.inverter_data', 'pv_') %}
{{ (pv_items | selectattr('id', 'equalto', 'pv_power1') | map(attribute='val') | first) | float }}
unit_of_measurement: "W"
device_class: "power"
state_class: "measurement"
- name: "Battery Voltage"
state: >
{% set bt_items = state_attr('sensor.inverter_data', 'bt_') %}
{{ (bt_items | selectattr('id', 'equalto', 'bt_battery_voltage') | map(attribute='val') | first) | float }}
unit_of_measurement: "V"
device_class: "voltage"
state_class: "measurement"
- name: "Battery Power"
state: >
{% set bt_items = state_attr('sensor.inverter_data', 'bt_') %}
{% set discharge_current = (bt_items | selectattr('id', 'equalto', 'bt_battery_discharge_current') | map(attribute='val') | first) | float %}
{% set charging_current = -((bt_items | selectattr('id', 'equalto', 'bt_battery_charging_current') | map(attribute='val') | first) | float) %}
{% set battery_voltage = (bt_items | selectattr('id', 'equalto', 'bt_battery_voltage') | map(attribute='val') | first) | float %}
{% set battery_current = charging_current + discharge_current %}
{{ (battery_current * battery_voltage) | float }}
unit_of_measurement: "W"
device_class: "power"
state_class: "measurement"
- name: "Battery SOC"
state: >
{% set bt_items = state_attr('sensor.inverter_data', 'bt_') %}
{{ (bt_items | selectattr('id', 'equalto', 'bt_battery_capacity') | map(attribute='val') | first) | float }}
unit_of_measurement: "%"
device_class: "battery"
state_class: "measurement"
- name: "Battery Discharge Current"
state: >
{% set bt_items = state_attr('sensor.inverter_data', 'bt_') %}
{{ -((bt_items | selectattr('id', 'equalto', 'bt_battery_discharge_current') | map(attribute='val') | first) | float) }}
unit_of_measurement: "A"
device_class: "current"
state_class: "measurement"
- name: "Battery Charging Current"
state: >
{% set bt_items = state_attr('sensor.inverter_data', 'bt_') %}
{{ (bt_items | selectattr('id', 'equalto', 'bt_battery_charging_current') | map(attribute='val') | first) | float }}
unit_of_measurement: "A"
device_class: "current"
state_class: "measurement"
- name: "Battery Current"
state: >
{% set bt_items = state_attr('sensor.inverter_data', 'bt_') %}
{% set discharge_current = (bt_items | selectattr('id', 'equalto', 'bt_battery_discharge_current') | map(attribute='val') | first) | float %}
{% set charging_current = -((bt_items | selectattr('id', 'equalto', 'bt_battery_charging_current') | map(attribute='val') | first) | float) %}
{{ (charging_current + discharge_current) | float }}
unit_of_measurement: "A"
device_class: "current"
state_class: "measurement"
- name: "Battery Current Direction"
state: >
{% set bt_items = state_attr('sensor.inverter_data', 'bt_') %}
{% set charging_current = (bt_items | selectattr('id', 'equalto', 'bt_battery_charging_current') | map(attribute='val') | first) | float %}
{{ 1 if charging_current > 0 else 0 }}
- name: "Load Output Voltage"
state: >
{% set bc_items = state_attr('sensor.inverter_data', 'bc_') %}
{{ (bc_items | selectattr('id', 'equalto', 'bc_load_voltage') | map(attribute='val') | first) | float }}
unit_of_measurement: "V"
device_class: "voltage"
state_class: "measurement"
- name: "Load Power"
state: >
{% set bc_items = state_attr('sensor.inverter_data', 'bc_') %}
{{ (bc_items | selectattr('id', 'equalto', 'bc_load_active_power') | map(attribute='val') | first) | float }}
unit_of_measurement: "W"
device_class: "power"
state_class: "measurement"
- name: "AC input voltage range" # APL = 90-280VAC | UPS = 170-280VAC
state: >
{% set gd_items = state_attr('sensor.inverter_data', 'gd_') %}
{{ (gd_items | selectattr('id', 'equalto', 'gd_ac_input_range') | map(attribute='val') | first ) }}
- name: "Battery type" # type AGN, USE, LIB, LIC, LIP, LIL
state: >
{% set bt_items = state_attr('sensor.inverter_data', 'bt_') %}
{{ (bt_items | selectattr('id', 'equalto', 'bt_battery_type') | map(attribute='val') | first ) }}
- name: "Charger source priority" # To configure charger source priority
state: >
{% set bt_items = state_attr('sensor.inverter_data', 'bt_') %}
{{ (bt_items | selectattr('id', 'equalto', 'bt_charger_source_priority') | map(attribute='val') | first ) }}
- name: "Output source priority" # To configure loat power source priority
state: >
{% set bc_items = state_attr('sensor.inverter_data', 'bc_') %}
{{ (bc_items | selectattr('id', 'equalto', 'bc_output_source_priority') | map(attribute='val') | first ) }}