seting of time via serial ASCII telegram #8

Open
Jusufs opened this issue Apr 11, 2022 · 1 comment
Open

seting of time via serial ASCII telegram #8

Jusufs opened this issue Apr 11, 2022 · 1 comment

Comments

@Jusufs
Copy link

Jusufs commented Apr 11, 2022

Hi,
do you know how to set time of US3000 via serial ASCII command please ?

Usage from help doesn't works.

time 2022 4 11 9 59 0
Invalid command or fail to execute.

Usage:
Time - time [year] [month] [day] [hour] [minute] [second]

But how is US3000 synchronized with inverter Studer XTM, XTH ?
Over Studer CAN Adapter from xtender ?

Thanks for help.
Jozef from Slovakia

@IVI053
Copy link

IVI053 commented Jun 7, 2022

All parts need to be two (2) digits:
time 22 04 11 09 59 00 will work