Skip to content

Commit

Permalink
Merge pull request #1381 from helmar74/patch-1
Browse files Browse the repository at this point in the history
Update Smart-Meter-Interface.md
  • Loading branch information
gemu2015 authored Nov 5, 2024
2 parents f3de664 + b8b9988 commit e57c16e
Showing 1 changed file with 48 additions and 1 deletion.
49 changes: 48 additions & 1 deletion docs/Smart-Meter-Interface.md
Original file line number Diff line number Diff line change
Expand Up @@ -1170,7 +1170,54 @@ For SGM-C4 or SGM-D4, double-tariff variants or meters measuring supply remove t

Overview of the codes
![image](https://user-images.githubusercontent.com/5443580/186160623-3db77d01-429f-49db-86ff-d804578aad99.png)


### EFR SGM-D4A920N
By default, the energy meter only sends the total energy values. To be able to read all the other values, you need to enter the PIN and set `InF on`. (can be done with "optical" button)
The PIN must be requested from the metering provider, which is usually your local grid provider and not your energy provider (but they know whom to ask). After entering the PIN and setting `InF on`, all the values will be available.
A few values I wasn't able to figure out, but the most relevant are there. If you want to try this parameters you have to comment out the lines (remove leading ;)

??? summary "View script"
```
>D
>B
spinm(4 1)
=>sensor53 r
>M 1
+1,3,s,0,9600,sml
1,77070100010800FF@1000,Bezug (180),kWh,zaehlerstand_180,3
;1,77070100010801FF@1,Tarif 1 (180),Wh,zaehlerstand_tarif_1_180,3
;1,77070100010802FF@1,Tarif 2 (180),Wh,zaehlerstand_tarif_2_180,3
1,77070100020800FF@1000,Einspeisung (280),kWh,zaehlerstand_280,3
;1,77070100020801FF@1,Tarif 1 (280),Wh,zaehlerstand_tarif_1_280,3
;1,77070100020802FF@1,Tarif 2 (280),Wh,zaehlerstand_tarif_2_280,3
1,770701000E0700FF@1,Netz Frequenz,Hz,netz_frequenz,1
1,77070100100700FF@1,aktuelle Wirkleistung,W,aktuelle_wirkleistung,0
1,770701001F0700FF@1,Strom L1,A,strom_l1,2
1,77070100200700FF@1,Spannung L1,V,spannung_l1,1
1,77070100240700FF@1,Wirkleistung L1,W,wirkleistung_l1,0
1,77070100330700FF@1,Strom L2,A,strom_l2,2
1,77070100340700FF@1,Spannung L2,V,spannung_l2,1
1,77070100380700FF@1,Wirkleistung L2,W,wirkleistung_l2,0
1,77070100470700FF@1,Strom L3,A,strom_l3,2
1,77070100480700FF@1,Spannung L3,V,spannung_l3,1
1,770701004C0700FF@1,Wirkleistung L3,W,wirkleistung_l3,0
1,77070100510701FF@1,Phasenwinkel U L1/L2,°,phasenwinkel_u_l1_l2,0
1,77070100510702FF@1,Phasenwinkel U L1/L3,°,phasenwinkel_u_l1_l3,0
1,77070100510704FF@1,Phasenwinkel I/U L1,°,phasenwinkel_i_u_l1,0
1,7707010051070FFF@1,Phasenwinkel I/U L2,°,phasenwinkel_i_u_l2,0
1,7707010051071AFF@1,Phasenwinkel I/U L3,°,phasenwinkel_i_u_l3,0
;1,77070100600100FF@#,Seriennummer,,seriennummer,0
;1,7707010060320101@#,Hersteller,,hersteller,0
;1,7707010060320104@#,HW Version,,hw_version,0
;1,7707010060320204@#,HW Version PCB2,,hw_version,0
;1,7707010060320404@#,Parameter Version,,parameter_version,0
;1,77070100605A0201@#,FW Checksum,,fw_checksum,0
;1,77070100605A0202@#,Unbekannt 2,,unbekanntes_mqtt_topic_2,0
;1,7707010000020000@#,Firmware Version,,firmwareversion,0
;1,7707010000020001@#,Unbekannt 1,,unbekanntes_mqtt_topic_1,0

```
### Elster / Honeywell AS1440 (OBIS)
Based on Landis script with changed timings in the >F section, as AS1440 seems to be slower in responding.
Expand Down

0 comments on commit e57c16e